Loop Powered Analogue Addressable Base Sounder
Features:
- Low profile design
- Loop powered
- High sound output
- Three tones available
- High and standard volume settings
- Rotary address switches
|
 |
|
Intelligent Optical Smoke Beam Detector
Features:
- Combined transmitter and receiver unit
- Can be connected directly to the Analogue addressable loop
- Range 10-100m
- Sensitivity/threshold adjustment
- Operates in the visible light spectrum
- Visual indicators to aid alignment of beam
- Standby, fault and alarm Led indicators
- Integral horizontal and vertical beam alignment
- Drift compensation
- Optional - Remote engineers switch
- Optional - Heat pad kits and filters
- Vds approved to prEN54-12 and EN60825-1
|
 |
Addressable Control Output Module
Features:
- DIN rail mounting option
- Surface mounting option
- Tri-colour LED status indication
- Built-in short circut indicators
- Visible address selector switches
- LED status visible in 2 planes
- Plug in connectors
- Approved to GEA GEI 1-082 and CEA GEI 1-084
|
 |
Dual Input/Single Output Addressable Module
Features:
- Dual inputs
- Single relay output
- DIN rail mounting option
- Surface mounting option
- Tri-colour LED status indication
- Built-in short circut indicators
- Visible address selector switches
- LED status visible in 2 planes
- Plug in connectors
- Approved to GEA GEI 1-082 and CEA GEI 1-084
|
 |
Intelligent Duct Detector Housing
Features:
- Accomodates intelligent ionisation or optical detectors
- Continuous sensitivity monitoring and alarm verification from the panel
- Simple change of detector heads: twist-in, twist-out
- Easy and quick mounting to round or rectangular ducts
- Output for remote test station (seperate 24Vdc is required)
- Air velocity rating from 150-1200 meters per minute (500 to 4000 feet per minute)
- Rugged Noryl® housing (mounting portion)
- Clear Polycarbonate cover for convenient visual inspection of sampling tube filters
- Three year limited warranty
|
 |
AC/DC E Intelligent Duct Detector Housing
Features:
- Accomodates intelligent ionisation or optical detectors
- Continuous sensitivity monitoring and alarm verification from the panel
- Simple change of detector heads: twist-in, twist-out
- Easy and quick mounting to round or rectangular ducts
- Output for remote test station (seperate 24Vdc is required)
- Air velocity rating from 150-1200 meters per minute (500 to 4000 feet per minute)
- Clear Polycarbonate cover for convenient visual inspection of sampling tube filters
- Rugged Noryl® housing (mounting portion)
- Two form c-auxiliary contacts
- Powered outputs for remote LED and sounder/strobe (seperate 24 Vac/dc power required)
- Three year limited warranty
|
 |
High Sensitivity Analogue Addressable Smoke Detector
Features:
- Extremely high sensitivity LASER based smoke sensor
- Superior early warning performance
- Effective response to both fast flaming and slow smouldering fires
- Stable communication with high noise immunity
- 9 sensitivity levels(0.07 - 6.56%/m)
- Twin LEDs for 360° visibility
- Built-in test
- Third party tested to EN54-7:2000
|
 |
Addressable Manual Break Glass Call Point
Features:
- Direct decade addressing(01-99)
- Built-in electronics
- Fast response
- LED shows polling (optional) and activation
- Flush or surface mounting
- Up to 99 per loop (+99 analogue sensors
- LPCB approved
- Simple to test
- Designed to the requirements of BS5839 Part 2
- IP67 rated model
|
Standard Water Proof |
Addressable Monitor Modules
Features:
- Single or dual inputs
- DIN rail mounting option
- Surface mounting option
- Tri-colour LED status indication
- Built-in short circut indicators
- Visible address selector switches
- LED status visible in 2 planes
- Plug in connectors
- Approved to GEA GEI 1-082 and CEA GEI 1-084
|
 |
Optical Thermal Analogue Addressable Multisensor
Features:
- Optical and thermal sensors
- Microprocessor controlled with internal algorithms
- Enhanced signal processing for improved stability
- High immunity to unwanted alarms
- 2 autolearn sensitivity settings
- 3 fixed sensitivity photo thermal settings
- Twin LEDs for 360° visibilty
- Built-in test
- Third party certified to CEA 4021, EN54-7:2000 and EN54-5:2000
|
 |
Low Profile Smoke Detectors
Features:
- Low profile design
- Common base for optical, ionisation and thermal sensors
- Addressable-analogue communication
- Stable communication technique with noise immunity
- Low stand-by current
- Rotary decade 01 to 99 address switches
- Remote LED output as standard
- Dual LED design provides 360° viewing angle
- Visible LED's blink every time the detector is addressed (optional), and illuminate steady on alarm
- Built-in functional test switch activated by external magnet
- Optional relay, isolator, or sounder bases
- LPCB approved
|
Optical Detector Ionisation detector |
Addressable Audible Warning Devices
Features:
- Loop powered
- High sound output
- Low current consumption
- 5 tones available
- Deep or sealed back boxes (wall sounders only)
- Three volume settings as standard
- Available in red or white
- Sounders designed to meet EN54 part 3
- Rotary DECADE address switches (01-99)
|
Wall.jpg) Base |
Intelligent Thermal Detector
Features:
- Dual thermistors
- Rate of rise fixed temperature and high fixed temperature models
- Common base for optical, ionisation and thermal sensors
- Addressable-analogue communication
- Stable communication technique with noise immunity
- Low stand-by current
- Rotary decade 01 to 99 address switches
- Remote LED output as standard
- Dual LED design provides 360° viewing angle
- Visible LED's blink every time the detector is addressed(optional), and illuminate steady on alarm
- Built-in functional test switch activated by external magnet
` - Optional relay, isolator or sounder base
|
 |
Two Wire Conventional Zone Interface
Features:
- Supports compatible two wire smoke detectors
- Supervises wiring and connection of external power source
- High noise (EMI/RFI) immunity
- SEMS screws with clamping plates for ease of wiring
- Two rotary switches for direct dial entry of decade address (01 to 99)
- LED flashes during normal operation
- LED latches steady to indicate alarm on command from control panel
|
 |
Loop Powered Analogue Addressable Wall Sounder
Features:
- Low profile design
- Loop powered
- High sound output
- Low current consumption
- Three tones available
- High and standard volume settings
- Available in red or white
- Rotary address switches
|
Red Base |
ZX Addressable Panels
|  |
ZX1e Multi-protocol Fire Alarm Control Panel
Features:
- Multi protocol
- Modular concept
- Simple robust design
- Intuitive to use
- Easy to maintain
- Easy to expand
- Easy to install
- Easy to configure
|
 |
ZX2e Multi-protocol Fire Alarm Control Panel
Features:
- Multi protocol
- Modular concept
- Simple robust design
- Intuitive to use
- Easy to maintain
- Easy to expand
- Easy to network
- Easy to install
- Easy to configure
|
 |
ZX5e Multi-protocol Fire Alarm Control Panel
Features:
- Multi protocol
- Modular concept
- Simple robust design
- Intuitive to use
- Easy to maintain
- Easy to expand
- Easy to network
- Easy to install
- Easy to configure
|
 |
ZX Series Printer Options
Features:
- Compatible with ZX series multi protocol intelligent fire alarm control panels
- Internal (ZXe/ZX5e) and external printer options
- External printer option:
- Intuitive to use
- Local or remote connection options
- Built-in 230Vac or 110Vac power supply and battery charger
- 4 LED status indictaions up to 1.2KM (3937 ft) from the fire panel (peripheral bus connection - RS485)
- Up to 31 remote printers can be connected to the peripheral bus
|
.jpg) |
Addressable Repeater Panels (Passive & Active)
Features:
- Compatible with Morley IAS intelligent multi-protocl fire alarm control panels
- Connects to RS485 peripheral bus
- Active or passive options
- Backlit adjustable alphanumeric display
- General Status LEDs
- Controls for system reset, accept, mute silence alarms and self test (active repeater only)
- "Access Enable" key-switch on active repeater
|
Passive Active |
Dimension Panels |
 |
Dimension 1 Loop Addressable Panels
Features:
- Complies with EN54 part 2 and part 4
- Optional 20 or 40 fire zones
- 2 independent sounder circuts
- 500mA Universal loop driver
- Supports Apollo (Xplorer, XP95 and discovery) Hochiki (ESP), Morley IAS and System Sensor
- 7 day timers
- Day/Night mode switching
- Onboard monitored inputs
- Programmable user function keys
- Event logging
- Onboard diagnostics
- User access restriction
- All metal enclosure
- Plug-in connectors
- Optional internal printer
- PC configuration software (optional)
|
 |
Dimension 2 Loop Addressable Panels
Features:
- Complies with EN54 part 2 and part 4
- 40 fire zone LED indicators
- 2 independent sounder circuts
- 500mA Universal loop driver
- Supports Apollo (Xplorer, XP95 and discovery) Hochiki (ESP), Morley IAS and System Sensor
- 7 day timers
- Day/Night mode switching
- Onboard monitored inputs
- Programmable user function keys
- Event logging
- Onboard diagnostics
- User access restriction
- All metal enclosure
- Plug-in connectors
- Optional internal printer
- PC configuration software (optional)
|
 |
Dimension 4 Loop Addressable Panels
Features:
- Complies with EN54 part 2 and part 4
- 40 fire zone LED indicators
- 2 independent sounder circuts
- 500mA Universal loop driver
- Supports Apollo (Xplorer, XP95 and discovery) Hochiki (ESP), Morley IAS and System Sensor
- 7 day timers
- Day/Night mode switching
- Onboard monitored inputs
- Programmable user function keys
- Event logging
- Onboard diagnostics
- User access restriction
- All metal enclosure
- Plug-in connectors
- Optional internal printer
- PC configuration software (optional)
|
 |